Fiber Distribution Box
-
FTTH Distribution Box
-
Cable Distribution Box
-
LSA Plus Module
-
MDF Main Distribution Frame
-
Subscriber Terminal Block
-
Rack Mount Patch Panel
-
RJ45 Keystone Jack
-
Horizontal Cable Manager
-
Network Cable Faceplate
-
110 Terminal Block
-
ODF Optical Distribution Frame
-
Optical Fiber Patch Cord
-
Fiber Optic Splice Closure
-
IDC Terminal Block
-
Network Punch Down Tool
-
Fiber Optic Accessories
-
ONU OLT
-
Andreas SandvikVery experienced manufacturer!!
-
Kristober GomezA Reliable, Trusted and Experienced Manufacturer You Can Count On
-
ilker ErimezThey gave complete solutions of Telecommunication.
-
احمد عبداللهYour AMP TYCO picabond connectors used for Iran telecom works excellent,our client is very satisfied with the quality.
10 Pair LSA Plus Module Grey Connection Module Silver Plating For Krone Type
Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xMaterial | ABS / PBT | Contact | Brass Or Phosphor Bronze |
---|---|---|---|
Plating | Nicle Base, Sliver Plate | Specification | Disconnection Or Connection |
OEM | YES | Application | Mount On The Back Mount Frame |
Highlight | krone connection module,krone disconnection module |
10 Pair LSA PROFILE Grey Connection Module for Krone Type
Material
Plastic component | ABS or PBT (UL-94V0) |
Contact material | Phosphor bronze or Brass |
Contact plating | Silver plating |
Mechanical Performance | Insertion force : 40~75N |
Pull Out Force : F≥25N(axial) F≥7.5N(radial) | |
IDC Life : 200 times(20-26 AWG Solid wire) minimum | |
Copper Conductor Diameter: Φ0.4~Φ0.8(mm) | |
Environment Characteristic | Storage Tempreture: 40 to 70°C |
Operating Temperature : 10 to 60°C | |
Relative Humidity: 95%, noncondition | |
Electrical Performance | Insulation resistance: 1000 Mohms minimum |
Contact resistance:7 mohms maximum | |
Dielectric intensity: AC 1000 Vrms 50Hz or 60Hz in 60s
|
Features :
Based on genuine LSA-PLUS Connection technology.
Avaiable in 10 pair configuration with parallel test access or overvoltage protection contact.
LSA-PLUS module mount on back mount frame.
LSA-PROFIL modules mount on profile rods (8-pair modules: 75mm spacing between rods; 10-pair modules:95mm spacing between rods) or back mount frame.
Suitable for use in all xDSL and ADSL2+ circuits.
Robust long-term environment stability allows both indoor and outdoor installation.
Supports all LSA-PLUS Series 2 accessories :
Overvoltage protection magazine.
Labels & Test and connection cords.
Specification :
Transient voltage : 2.5 kV.
Operation voltage for basic insulation : 210 VDC TNV.
Pollution severity : II.
Current - carrying capacity : 2 A.
Impulse current : 5 kA ( 8 / 2µs ).
Single solid wire per contact : 0.35 mm / 0.68 mm to 0.9 mm / 1.5 mm.
Stranded wires : 0.12mm to 0.32 mm / up to 2.1 mm AWG 28 to AWG 20.
Overall diameter of connectable wire : 0.68 mm to 1.6 mm (solid insulation ).
Storage Temperature: - 40 °C to + 90 °C.
Transport Temperature : - 40 °C to + 90 °C.
Operation Temperature : - 5 °C to + 60 °C.
Relative humidity : < 95% ; no water condensation, no ice.